Hello. New customer? Start here.   
Home    About Us    Contact Us    Order Status    Wish List    Login 
? View Items In Your Shopping Cart Shopping Cart is Empty 
 

Search
Advanced Search

Shop with Confidence
  
  
  Lowest Price Guarantee
  
  
  
  
  

 
 
 
Generac-Guardian-5870
View Larger
 
Model 5870 8 kW w/ 10 Circuit ATS
Item#:  Generac-5870
MSRP:  2,432.00
Our Price:  2,111.00
Qty: 
 
Extended Warranty:  
Cold Weather Kit:  
Maintenance Kit:  
Transfer Switch:  
 

Generac Guardian 8 kW Model 5870 with

10 Circuit Automatic Load Center Transfer Switch
(Steel Housing)
(No Sales Tax, Free Freight, Home Delivery)

guardian_series_liquid

Fully Automatic Home Standby Generator (NG/LP)

guardian_series_8KW(1)
NEXUS SMART SYSTEM

Includes:

  • Generac LP or Natural Gas Engine
  • Trupower Technology for Sensative Circuits
  • Two Line LCD Digital Nexus™ Controller
  • Automatic Transfer Switch
  • Composite Mounting Pad
  • Flexible Fuel Line
  • Prewired Electrical Conduit Box
  • Isochronous Electronic Governor
  • Smart Battery Charger
  • UV/Ozone Resistant Hoses
  • ±1% Voltage Regulation
  • High efficiency, low distortion alternator
  • UL2200 Listed
  • Sound attenuated acoustic enclosure
  • Electrostatically applied powder paint
  • Whisper-Test™ low noise level exercise
  • Acoustically designed engine cooling system
  • High flow low noise exhaust system
  • Watertight electrical connectors
  • Vibration isolated from mounting base
  • Easily accessible for maintenance
  • Rodent proof construction

Model Number

5870

Rated Power (LP / NG)

8/7 kW

Rated Amps @ 240 V (LP/NG)

33.3/29.5

Surge Watts - 240V, 1 Ø

12,690

Surge Amps

52

Engine (Generac OHVI)

410 cc / Single

Alternator RPM

3600

Enclosure

Steel

Whisper Test

No

Sound Level (dBA @ exercise)

62

(dBA @ normal operation)

62

Dimensions (L"xW"xH")

48x25x29

Transfer Switches

100 Amp / 10 circuit

Unit Weight (lbs.)

340

Full Spec Sheet

Specification Sheet

VIEW GENERATOR DRAWING

TRANSFER SWITCH DRAWING

Need to Know Gas Piping Sizes?

Generac's Nexus™ Controller is the most comprehensive available. The dual line, tri-lingual LCD display allows for easy monitoring and management of generator functions.

Simple field conversion from natural gas to LP.

Generac OHVI Engine was designed specifically for generators. It out peforms most competitive generator engines with an engine life that is three to four times longer and has a significantly longer period between scheduled maintenance checkups.

Trupower Technology provides clean, smooth operation of sensitive electronics and appliances.

Sturdy, galvanneal steel enclosure with RhinoCoat™ finish for superior weather protection, modeled to withstand 150 mph winds.

External “At-a-Glance” indicator lights offer an easy way to tell generator status without opening the generator enclosure.

Added Sound Reduction with enclosures that are lined with sound reducing foam panels for further noise reduction.

Hour Meter monitors run time, providing information to determine maintenance intervals.

Easiest installation on the market and an excellent value when purchased pre-packaged with a pre-wired transfer switch, or customize your system by purchasing the generator and transfer switch separately. Composite mounting pad is included, eliminating the need to pour a concrete base.

GENERAC-B001DZNDFK-2-lg

Generator Features:

  • External GFCI Outlet
  • Composite Mounting Pad
  • Pre-wired External Connection Box
  • External Main Circuit Breaker,
  • GFCI Duplex Outlet
  • Flexible Fuel Line Connector
  • Natural Gas or LP Gas Operation
  • Weekly Exercise Timer

View Full Line Generac Brochures

Additional Questions See our FAQS.

16-circuit_transfer_switch

EZ Transfer Switch Features:

  • 10 Circuit EZ Automatic Transfer w/ Priority Load Center
  • Electrically operated, mechanically-held contacts for fast, positive connections.
  • Rated for all classes of load, 100% equipment rated, both inductive and resistive.
  • 2 pole, 250 VAC contactors.
  • 160 millisecond transfer time.
  • Dual coil design.
  • Main contacts are silver plated or silver alloy to resist welding and sticking.
  • NEMA 1 (indoor rated) enclosure is standard on the 100 amp switch.
  • Pre-wired 30 foot whip to connect to the pre-wired external connection box.
  • Pre-wired 2 foot whip, color coded to connect into the existing electrical panel.

 

The Power Behind the #1 Home Standby Generator

Geneac OHVI® engine

Generac has engineered and manufactures the only true generator engine.Why is this important? Generators are often required to run for hours at a time, day after day. Generac’s OHVI engine utilizes the same type of pressurized oil lubrication used to give automobile engines long and trouble free lives. This means a significantly longer life than competitive engines - an unprecedented three to four times longer.

generac-ohvi-chart-lg
View the OHVI Engine Video
How Automatic Standby Generators Work

New for 2010

upgrade

benefit

Nexus LCD digital trilingual controllers

Technologically advanced intelligent controls

External breaker connections on all units

Allows for electricity shut-off without opening / unlocking the enclosure for safety (code compliant)

180º swing capability on breaker box door

Allows for full range of motion for ease of access during installation and servicing

Prop rod for breaker box door

Allows door to stay open during connection and service

Increased fan size and scroll elimination

Better cooling capacity and tonal quality = quiet operation

Electronic governing and brushed alternators on all units

Precision engine response and voltage control for fast reaction when loads are applied

Torq screws replaced with common screws

Special tools no longer required

Improved structural integrity

Modeled to withstand 150 mph winds on both steel and aluminum enclosures

Expanded cold weather accessories

Ensures maximum generator performance in cold climates

Snap-in remote accessory cover plate

Easy remote monitor installation

Spade connectors replace ring terminals on low oil sensor

Quick disconnecting for service and diagnostic capability

NEXUS CONTROLLER FEATURES

The new Nexus controller for air-cooled generators (8 -20 kW) not only includes upgraded features available in the original controller, but also includes several new features, making it the most comprehensive air-cooled controller available.

External common fault alarm

Allows for a connection to drive a common alarm if any shutdown for the generator occurs (i.e., security system, home automation integration)

Wiring error

Gives indication if transfer switch is connected incorrectly without allowing board damage

Battery sentinel

Monitors the battery to indicate that the battery is going to fail or if it has failed

Generator high voltage shutdown

Shuts down generator at preset levels to avoid high voltage damage to appliances

Generator low voltage shutdown

Shuts down generator at preset levels when voltage dips too low

Internal fault shutdown

Shuts down generator in event of controller failure

Master Nexus Controller includes voltage regulator, battery charger and engine controller

+/-1% voltage regulation, smart charging battery system where output voltage is dependent upon ambient temperature and only charges the system when needed

now available on all models:

LCD display and keyboard Remote maintenance LEDs Time & date Alarm log Run log

Set exercise via display Engine hour display RPM display & sensor loss alarm Frequency Battery voltage, Underspeed/fail to transfer alarm, High engine temperature alarm, Low oil, display Trilingual display

Installation Overview

generac_connec2
  • All conduits are color coded and prewired
  • Select the circuits needed during emergency
  • Jumper the circuits over to the Generat EZ panel
  • Selected Circuits come on during loss of power from the utility
  • Once power is restored from the utility the transfer switch will transfer back and the generator will shutdown
  • Time to transfer is only 20 seconds

GENERATOR SIZING

By sizing your generator according to your needs instead of your home’s square footage, you won’t overspend or be surprised by inadequate coverage. Decide what items are important to you in a power outage. these items are powered through circuits in your breaker box. the number of chosen circuits decides your generator size. Use this chart as a guide to determine the power you need.

Generator Size

8 kw

10 kw

12 kw

14 kw

16 kw

20 kw

Number of Circuits

8

10

12

14

16

Whole House

Air conditioning

2-ton

3-ton

3-ton

up to 4-ton*

up to 5-ton*

up to 5-ton*

Kitchen

-

-

-

-

-

-

Furnace

-

-

-

-

-

-

Sump Pump

-

-

-

-

-

-

Bathrooms on Emergency

1

1

2

2

3

3+

Bedrooms on Emergency

1

2

3

4

5

5+

Living Areas

-

-

-

-

-

-

Well Pump or Heater

 

-

-

-

-

-

Home Office

 

 

-

-

-

-

Garage

 

 

-

-

-

-

 

Generac_Guardian_5872_5871_5870


I have this product, and I want to Review it

Generac Guardian Model 5636 Remote Monitor
329.00
  View this product

 
 


Generac Guardian Quietsource 130 kW
Generac Guardian QT13068 130 KW Generator
24,767.00

Kohler 18RESL 18 kW with 200 Amp Automatic Transfer Switch
Kohler 18RESL 18 Kw Generator