Hello. New customer? Start here.   
Home    About Us    Contact Us    Order Status    Wish List    Login 
 

Search
Advanced Search

Shop with Confidence
  
  
  Lowest Price Guarantee
  
  
  
  

 
 
 
Generac
Generac-Guardian-5875
View Larger
 
Model 5875 20 kW Generator with 200 Amp Whole House Switch
 
5.0
Read 1 ReviewWrite a Review
 
  Share  
 
Item#:  Generac-5875
MSRP:  5,887.00
Our Price:  4,497.00
You Save:  1,390.00 (24%)
Qty: 
 
Extended Warranty:  
Cold Weather Kit:  
Maintenance Kit:  
Transfer Switch:  
Battery: 
 

Generac Guardian 20 kW Model 5875 with

200 Amp RTS-D-200A3 Automatic Transfer Switch With
Service Disconnect & Digital Load Management
(Aluminum Housing)
(new model replacing Model 5875 - See Model 6244)

guardian_series_liquid

Fully Automatic Home Standby Generator (NG/LP)

guardian_series_20KW
NEXUS SMART SYSTEM

Includes:

  • Generac LP or Natural Gas Engine
  • Trupower Technology for Sensative Circuits
  • Two Line LCD Digital Nexus™ Controller
  • Automatic Transfer Switch
  • Composite Mounting Pad
  • Flexible Fuel Line
  • Prewired Electrical Conduit Box
  • Isochronous Electronic Governor
  • Smart Battery Charger
  • UV/Ozone Resistant Hoses
  • ±1% Voltage Regulation
  • High efficiency, low distortion alternator
  • UL2200 Listed
  • Sound attenuated acoustic enclosure
  • Electrostatically applied powder paint
  • Whisper-Test™ low noise level exercise
  • Acoustically designed engine cooling system
  • High flow low noise exhaust system
  • Watertight electrical connectors
  • Vibration isolated from mounting base
  • Easily accessible for maintenance
  • Rodent proof construction

Model Number

5875

Rated Power (LP / NG)

20/18 kW

Rated Amps @ 240 V (LP/NG)

83.3/75

Surge Watts - 240V, 1 Ø

35,470

Surge Amps

147

Engine (Generac OHVI)

999 cc / V-twin

Alternator RPM

3600

Enclosure

Aluminum

Whisper Test

Yes

Sound Level (dBA @ exercise)

60

(dBA @ normal operation)

66

Dimensions (L" x W" x H")

48x24x28

Compatible Transfer Switches

200 Amp w/ Service Disc.

Unit Weight (lbs.)

455

Full Spec Sheet

Specifications Sheet

VIEW GENERATOR DRAWING

TRANSFER SWITCH DRAWING

Need to Know Gas Piping Sizes?

Generac's Nexus™ Controller is the most comprehensive available. The dual line, tri-lingual LCD display allows for easy monitoring and management of generator functions.

Simple field conversion from natural gas to LP.

Generac OHVI Engine was designed specifically for generators. It out peforms most competitive generator engines with an engine life that is three to four times longer and has a significantly longer period between scheduled maintenance checkups.

Trupower Technology provides clean, smooth operation of sensitive electronics and appliances.

Sturdy, Aluminum enclosure with RhinoCoat™ are naturally rust and corrosion resistant. For salt air or high humidity conditions, aluminum is highly recommended to ensure decades of worry free service.

External “At-a-Glance” indicator lights offer an easy way to tell generator status without opening the generator enclosure.

Added Sound Reduction with enclosures that are lined with sound reducing foam panels for further noise reduction.

Hour Meter monitors run time, providing information to determine maintenance intervals.

Easiest installation on the market and an excellent value when purchased pre-packaged with a pre-wired transfer switch, or customize your system by purchasing the generator and transfer switch separately. Composite mounting pad is included, eliminating the need to pour a concrete base.

GENERAC-B001DZNDFK-2-lg

Generator Features:

  • External GFCI Outlet
  • Composite Mounting Pad
  • External Main Circuit Breaker,
  • GFCI Duplex Outlet
  • Flexible Fuel Line Connector
  • Natural Gas or LP Gas Operation
  • Weekly Exercise Timer

View Full Line Generac Brochures

Additional Questions See our FAQS.

Revolutionary way to complete the standby generator system, the combination of the Nexus Smart Switch and the Nexus Controller adds up to Generac’s Nexus Smart System. The smartest air-cooled switch/controller system available, It efficiently manages two large loads without additional components, a function not possible with a standard transfer switch. Add optional Digital Load Management (DLM) modules for intelligent management of up to four more loads. It also provides the most comprehensive display of alarms and system stats. From monitoring to load management, owning a standby generator system has never been easier.

NEXUS_SYSTEM

How it works

    · By monitoring generator engine performance, the switch is able to identify when the generator approaches overload. At the appropriate time, the switch disconnects two air conditioners, typically the highest electrical load in the house.

    · After a 5-minute delay to allow for compressor bleed out, the switch brings the AC units back online one after the other with a 30-second delay in between. This is a standard capability in all Generac Smart Switches and does not require any additional components, unlike competitive transfer switches.

    · In addition, up to four other large 240V loads can be managed when the Smart Switch is used in conjunction with individual DLM modules. These modules are 50 amps each and are housed in a NEMA 3R enclosure, giving the installer the option to install them either at the electrical panel or anywhere in-line indoors or outdoors between the electrical panel and the appliance. After the four loads are shed, they are brought back individually to assure DLM Module generator capability and eliminate the potential of overload.

Nexus-Smart-Switch2

Whole House Coverage with Load Management

200 Amp Automatic Transfer Switch w/ DLM Module to Shed Two AC Units.

RTSD200A3

RTS-D-200A3

SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCH INCLUDED

DLM Module

DLM_module

NEXUS Controller

nexus controller

Cycle on and off two air conditioners without additional components, allowing for a smaller generator to cover more circuits.

 

generac load shed module

Installation Overview

RTSD SERIES

GFCI Plug On Outside Of Generator

  • Whole House Transfer
  • Automatic Transfer Switch is Service Entrance Rated with a 200 amp transfer switch to disconnect utility power.
  • No need to select the circuits needed during emergency
  • All Circuits come on during loss of power from the utility
  • Once power is restored from the utility the transfer switch will transfer back and the generator will shutdown
  • Time to transfer is only 20 seconds
Generac Outside breaker
How Automatic Standby Generators Work
View the OHVI Engine Video

 

The Power Behind the #1 Home Standby Generator

Geneac OHVI® engine

Generac has engineered and manufactures the only true generator engine.Why is this important? Generators are often required to run for hours at a time, day after day. Generac’s OHVI engine utilizes the same type of pressurized oil lubrication used to give automobile engines long and trouble free lives. This means a significantly longer life than competitive engines - an unprecedented three to four times longer.

generac-ohvi-chart-lg

New for 2010

upgrade

benefit

Nexus LCD digital trilingual controllers

Technologically advanced intelligent controls

External breaker connections on all units

Allows for electricity shut-off without opening / unlocking the enclosure for safety (code compliant)

180º swing capability on breaker box door

Allows for full range of motion for ease of access during installation and servicing

Prop rod for breaker box door

Allows door to stay open during connection and service

Increased fan size and scroll elimination

Better cooling capacity and tonal quality = quiet operation

Electronic governing and brushed alternators on all units

Precision engine response and voltage control for fast reaction when loads are applied

Torq screws replaced with common screws

Special tools no longer required

Improved structural integrity

Modeled to withstand 150 mph winds on both steel and aluminum enclosures

Expanded cold weather accessories

Ensures maximum generator performance in cold climates

Snap-in remote accessory cover plate

Easy remote monitor installation

Spade connectors replace ring terminals on low oil sensor

Quick disconnecting for service and diagnostic capability

NEXUS CONTROLLER FEATURES

The new Nexus controller for air-cooled generators (8 -20 kW) not only includes upgraded features available in the original controller, but also includes several new features, making it the most comprehensive air-cooled controller available.

External common fault alarm

Allows for a connection to drive a common alarm if any shutdown for the generator occurs (i.e., security system, home automation integration)

Wiring error

Gives indication if transfer switch is connected incorrectly without allowing board damage

Battery sentinel

Monitors the battery to indicate that the battery is going to fail or if it has failed

Generator high voltage shutdown

Shuts down generator at preset levels to avoid high voltage damage to appliances

Generator low voltage shutdown

Shuts down generator at preset levels when voltage dips too low

Internal fault shutdown

Shuts down generator in event of controller failure

Master Nexus Controller includes voltage regulator, battery charger and engine controller

+/-1% voltage regulation, smart charging battery system where output voltage is dependent upon ambient temperature and only charges the system when needed

now available on all models:

LCD display and keyboard Remote maintenance LEDs Time & date Alarm log Run log

Set exercise via display Engine hour display RPM display & sensor loss alarm Frequency Battery voltage, Underspeed/fail to transfer alarm, High engine temperature alarm, Low oil, display Trilingual display

GENERATOR SIZING

By sizing your generator according to your needs instead of your home’s square footage, you won’t overspend or be surprised by inadequate coverage. Decide what items are important to you in a power outage. these items are powered through circuits in your breaker box. the number of chosen circuits decides your generator size. Use this chart as a guide to determine the power you need.

Generator Size

8 kw

10 kw

12 kw

14 kw

16 kw

20 kw

Number of Circuits

8

10

12

14

16

Whole House

Air conditioning

2-ton

3-ton

3-ton

up to 4-ton*

up to 5-ton*

up to 5-ton*

Kitchen

-

-

-

-

-

-

Furnace

-

-

-

-

-

-

Sump Pump

-

-

-

-

-

-

Bathrooms on Emergency

1

1

2

2

3

3+

Bedrooms on Emergency

1

2

3

4

5

5+

Living Areas

-

-

-

-

-

-

Well Pump or Heater

 

-

-

-

-

-

Home Office

 

 

-

-

-

-

Garage

 

 

-

-

-

-

 

Average Rating: 
5.0
  based on 1 Customer Reviews

Review On Aug 10, 2011 by Joe P. of Fordsville, KY
Rating:
Title: Great Investment
Comments: I have had my generator for three years. It has proven to be one of my better decisions. I am a master electrician and the install was simple and only took about a half-day of work. A local contractor roughly estimated the install, including LP gas hook-up) would cost about $750 to $1000. Again, mine was a simple install.
Fortunately, I have only had to rely on the generator a few times during power outages and storms. Each time, it performed flawlessly. The maintenance cycle is also a real comfort. I get a lot of attention from the neighbors about how I must have it made.

Generac Guardian GenReady Load Center
391.00
  View this product
Generac Guardian Model 5951 Remote Monitor
329.00
  View this product

 
 


Power Outages

ª Grab this Headline Animator