Hello. New customer? Start here.   
Home    About Us    Contact Us    Order Status    Wish List    Login 
? View Items In Your Shopping Cart Shopping Cart is Empty 
 

Search
Advanced Search

Shop with Confidence
  
  
  Lowest Price Guarantee
  
  
  
  
  

 
 
 
Generac Guardian RTSD100A3
View Larger
 
RTS-D-100A3 100 Amp Automatic Transfer Switch
120/240 V Single Phase
Item#:  RTS-D-100A3
MSRP  617.00
Our Price:  479.00
Qty: 
 

Generac Guardian 100 amp Automatic Transfer Switch w/ Service Disconnect

Model RTS-D-100A3

(120/240 V Single Phase)

 
 
generac-transfer-switches
 
 
Nexus-Smart-Switch
 
Non-service rated (RTS-D SERIES)
 
 
Model
RTSD100A3
RTSD200A3
RTSD400A3
Amps
100
200
400
Voltage
120/240, 1ø
120/240, 1ø
120/240, 1ø
Load Transition Type (Automatic)
Open Transition Service Rated
Open Transition Service Rated
Open Transition Service Rated
Enclosure Type
NEMA 3R
NEMA 3R
NEMA 3R
Withstand Rating (Amps)
10,000
22,000
22,000
Lug Range
2/0 - #14
400 MCM - #4
600 MCM - #4 or 2-250 MCM
Unit Weight – lbs.
22.5
39
140
kilos
9.97
17.69
63.5
 
The Nexus Smart Switch has the ability to manage two air conditioners without adding additional components or cost. Gain even more flexibility by adding up to our more individual DLM modules for additional load management.
100 - 400 Amp Service Entrance Rated Switch (RTS-D SERIES)
Our service entrance rated models include an integrated main breaker that eliminates the need for a separate service disconnect when backing up all of the electrical loads in a building.
All Smart Switches are housed in an aluminum NEMA/UL Type 3R enclosure, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The control at the generator handles all the timing, sensing and exercising functions.
Through the use of Digital Load Management technology (DLM), each of these switches has the capability to truly manage two air conditioning loads with no additional hardware. When used in tandem with the individual DLM modules, up to four more additional loads can be intelligently managed individually.
 
 
Item Number
Manual (PDF)
0H7446
MANUAL 100A&200A XFER SW S/D
0G6832
INSTALL 100/200A ENCLOSURE
 
 
WHEN TO USE THE RTS-D SERIES SWITCHES
WHOLE HOUSE TRANSFER
 
 
RTSD SERIES
 
 
 
1. By monitoring generator engine performance, the switch is able to identify when the generator approaches overload. At the appropriate time, the switch disconnects two air conditioners, typically the highest electrical load in the house.
2. After a 5-minute delay to allow for compressor bleed out, the switch brings the AC units back online one after the other with a 30-second delay in between. This is a standard capability in all Generac Smart Switches and does not require any additional components, unlike competitive transfer switches.
3. In addition, up to four other large 240V loads can be managed when the Smart Switch is used in conjunction with individual DLM modules.
  • DLM modules are 50 Amps each and are housed in a NEMA 3R enclosure, giving the installer the option to install them either at the electrical panel or anywhere in-line indoors or outdoors between the electrical panel and the appliance.
  • After the four loads are shed, they are brought back individually to assure DLM Module generator capability and eliminate the potential of overload.
 
 
DIGITAL LOAD SHED MODULE
 
 
 
generac load shed module
 
 
 
SEQUENCE OF OPERATION
  • The 4 green status LEDs will indicate when a load priority level is enabled.
  • All loads are enabled when the transfer signal is off. (ATS in Utility position).
    If the transfer signal is pulled low (Active)
  • All loads are enabled until an overload is detected
  • When an overload is detected all loads are disabled
  • After 5 minutes priority 1 loads are enabled.
  • After another 30 seconds priority 2 loads are enabled
  • After another 30 seconds priority 3 loads are enabled
  • After another 30 seconds priority 4 loads are enabled
If an overload is detected within 30 seconds of a level being enabled, all loads are disabled again and the sequence repeats. However, the level that caused the overload and all levels higher will not be enabled again for 30 minutes.
 

 



I have this product, and I want to Review it

 
 


Generac Guardian Quietsource 150 kW
Generac Guardian QT15068 150 KW Generator
26,879.00

Generac Guardian Quietsource 80 kW
Generac Guardian Elite Model QT08068 80 KW Generator
16,242.00

Generac Guardian RTSX200A3
RTS-X-200A3 100 Amp Automatic Transfer Switch
576.00

Generac Guardian RTSX100A3
RTS-X-100A3 100 Amp Automatic Transfer Switch
335.00

Generac-Guardian-5870
Model 5870 8 kW w/ 10 Circuit ATS
2,111.00